Cuprora/Technology
Match the process to the function.
SLA, aluminium, POM, inserts, pogo probes — each of these words only makes sense once you know what carries the load, what defines the geometry and what has to be replaceable.
LAYERS
How a fixture is built
From the bottom: an aluminium frame, a base plate, press guidance, the probe plate and a nest that locates the board. Every layer has a different job — which is why we don't make everything from one material.
-
01 / FRAME
Aluminium profile, carries the clamping load.
-
02 / BASE PLATE
Aluminium, the reference plane.
-
03 / PROBE PLATE
Probe plate, guided on posts.
-
04 / NEST
POM or printed, geometry for a specific board.
-
05 / INTERFACE
Translator or harness to the tester.
SLA or CNC? The answer depends on the part.
We don't claim that printing replaces machining. We claim that most fixture geometry does not need CNC — and the parts that do, we source.
| Criterion | SLA printing | CNC aluminium |
|---|---|---|
| Cost of the first part | Low — no programming or fixturing | High — program, setup, workholding |
| Geometry change | New file, another print | New program and new workholding |
| Tolerance | ±0.15 mm as printed; critical faces machined after | ±0.05 mm; hole position ±0.02 mm |
| Stiffness | E ≈ 10 GPa — cannot carry probe force | E ≈ 69 GPa — carries 1.5 kN |
| Threads and inserts | Epoxy-bonded or press-fit; heat-set does not work in a thermoset | Thread cut into the material |
| Thermal stability | HDT 82 °C; CTE 30–80 ppm/K | Continuous use to ~150 °C; CTE 23.6 ppm/K |
| When we choose it | Nest, housing, pockets, guides, prototype | Frame, probe plate, reference planes |
CALCULATION
Why the probe plate is not resin
Let's do the maths: 500 probes × 3 N is 1.5 kN. A 300 × 200 × 10 mm plate supported at its edges deflects by about 3.2 mm in Rigid 10K resin (E ≈ 10 GPa) and about 0.46 mm in 6061 aluminium (E ≈ 69 GPa). With supports every 100 mm the ratio is still an order of magnitude. That is why the probe plate is metal or FR4 on a metal support — and printing handles the nest, pockets and housing.
Simplified beam model, uniformly distributed load. This is not an FEA result — it is an order of magnitude that shows where resin stops working.
Materials we use
Nest, pockets, housings, guides. Rigid 10K or equivalent: E ≈ 10 GPa, HDT 82 °C. Never used for plates that carry probe force.
Frame, probe plate, reference planes. Cut and milled by a supplier, inspected on receipt.
Probe plates and insulators. E ≈ 20–24 GPa, CTE 12–16 ppm/K — more stable than POM or resin.
Enclosures, panels, guards. Bending and punching to order.
Bushings, sliding guides, low-friction parts. With creep and CTE of 110–120 ppm/K in mind.
Standard, high-current, Kelvin, RF — selected for current, pitch, force and life.
Brass inserts bonded with 2K epoxy or press-fit; class 8.8 screws; ESD components.
Pogo probes: four parameters that decide
The probe is not an accessory. It decides current, resistance and whether the fixture survives a year on the line.
Current
Standard 1–3 A; Ingun GKS-100 is rated 5 A at 20 mΩ, HSS-150 50 A at <10 mΩ. For higher currents we parallel probes or use a high-current series.
Pitch
1.27 mm, 1.9 mm, 2.0 mm, 2.54 mm. The finer the pitch, the harder the access and the more expensive the probe — GKS-050 is already a 1.27 mm probe.
Life
Catalogue figures run from 100k to over a million cycles under laboratory conditions. In production, spring, cleaning and guidance matter more than the datasheet.
Resistance
Typically 20–50 mΩ. For milliohm measurements we use Kelvin (4-wire) probes and a separate wire pair.
A probe specification, not “high-quality probes”
Every quote includes a probe specification: manufacturer, type, current, resistance, spring force, pitch, stated life and price. The customer sees what they pay for — and can buy a replacement themselves.
05 / ACCEPTANCE
An acceptance protocol, not an assurance
The first article does not leave the workshop without measurement. The test scope depends on the fixture, but the list is fixed before the build — and always ends with a report.
- Continuity and isolation — 100% of probes, report with values
- Clamping force and planarity — measured with a gauge, limit in the documentation
- Position repeatability — CMM/vision, 30 samples, ±0.05 mm CNC / ±0.15 mm SLA
- GR&R — on request, for critical measurements
- 1,000-cycle test — on the first article when in scope
- Package: STEP, pin map, BOM, instructions, service card
06 / STANDARDS
Standards — without certificates we don't hold
Assembly and harnesses follow IPC-A-610 class 2 and IPC/WHMA-A-620 as a quality reference, not as certification. Interface boards are designed to IPC-2221/2222. IPC-9252 applies to bare boards — we do not use it as evidence for assembled PCBA. We are implementing an ESD programme to ANSI/ESD S20.20. We do not hold ISO 9001 and do not claim it.
EVIDENCE POLICY
Every number on this site has a source: a measurement, a manufacturer document, or an explicit “to be validated”. We don't use “98%”, “120+” or “4.9” without data. If we haven't measured it, we say so.
Cuprora · Warsaw · 2026
See what's in the package
Gerber X2, ODB++, IPC-2581, STEP and a test point list. We reply within 24 business hours.